Part No: P144Issued year: 2016File size: 0.6mbFile type: pdf
The ability to extract a broad range of different drugs from a biological matrix allows for the expedited analysis of a patient sample using LC-MS/MS. Typically small molecules are extracted from matrices like urine based on their polarities. A fast and reliable sample preparation method that could be implemented to extract drugs of different polarities from urine could be used as a screening tool to quickly identify the presence of illicit drugs in patient samples using LC-MS-MS.
This poster demonstrates the utility of supported liquid extraction for the extraction of over 30 different acidic, basic and neutral drugs in urine prior to LC-MS/MS.
MSACL 2016
Part No: AN859Issued year: 2016File size: 0.93mbFile type: pdf
This application note describes the extraction of acidic, basic, and neutral drugs from urine for screening purposes using ISOLUTE® SLE+ supported liquid extraction plates prior to LC-MS/MS analysis.
Part No: P088Issued year: 2014File size: 1.06mbFile type: pdf
This poster evaluates the performance of a novel 96-well filter plate (ISOLUTE PLD+ Protein and Phospholipid Removal Plate) for
the simultaneous removal of proteins and phospholipids from serum samples prior to LC-MS/MS analysis.
ASMS2014
Part No: P104Issued year: 2014File size: 0.77mbFile type: pdf
This poster presents the ISOLUTE PLD+ Protein and Phospholipid removal plate, highlighting its ease of use and excellent performance with respect to sample clean up, analyte recovery and elimination of back pressure build up in the UPLC system.
IMSC 2014
Part No: AN837Issued year: 2015File size: 2.27mbFile type: pdf
This application note describes the extraction of 47 drugs
of abuse and metabolites from oral fluid matrix after sampling via Oral-Eze collection devices, prior to UPLC-MS/MS analysis using ISOLUTE SLE+ supported liquid extraction columns. Estimated LOQs of between 0.005 and 0.75 ng/mL (analyte dependant) are achieved,.
Part No: AN830Issued year: 2014File size: 1.44mbFile type: pdf
This application note describes the use of the ISOLUTE® PLD+ Protein and Phospholipid Removal Plate for clean-up of a range of acidic, basic and neutral drugs from plasma. ISOLUTE® PLD+ Protein and Phospholipid Removal Plates are suitable for clean-up of a range of analytes with widely differing functionality and polarity characteristics from plasma, giving high recoveries, good reproducibility and excellent extract cleanliness.
Part No: AN702Issued year: 2011File size: 0.11mbFile type: pdf
This Application Note describes the extraction of a variety of basic drugs from plasma using EVOLUTE® CX mixed-mode resin-based SPE. The analyte suite includes basic drugs with wide ranging pKa and logP values.
Basic Drugs, Biotage, Ion Exchange, EVOLUTE, Pharmaceuticals
Part No: AN806Issued year: 2013File size: 1.03mbFile type: pdf
The screening of patient urine samples for basic drugs is typically performed following a lengthy sample preparation methodology that requires a time consuming dry down step.
A novel elution protocol coupled to the EVOLUTE EXPRESS advanced plate technology affords a fast sample preparation solution that follows a LOAD-WASH-ELUTE-ANALYZE strategy. Basic drugs are fortified into urine and extracted in 3 easy steps using EVOLUTE EXPRESS CX solid phase extraction in a 96-well plate format.